the main cover must only be performed by an approved fitter or the manufacturer.

The heater should not be left for long periods without use. It is advisable to run the unit for

short periods throughout the summer.

The exhaust and inlet pipes should be inspected periodically for damage and any build-up

of dirt around the ends. Clean or replace as necessary.

The heater, its gas supply, and flues for the products of combustion are to be inspected in

accordance with national regulations or if these do not exist, the manufacturer's

recommendations, however, it is advised that this should be done at least annually.

Lockout Clearing Procedure

The lockout must be cleared by turning the 'Fan Only' setting on the control panel, 'on', 'off'

and 'on' again within 2.5 seconds. If the first lockout reset attempt is unsuccessful, you can

retry an additional 4 times. If the lockout still will not clear (identified by a solid LED), please

turn off the heater, check the heater for faults, power up the heater and then further lockout

reset attempts can be made.

Manufactured By: Munster Simms Engineering

Distributed by; PROPEX HEATING & LEISURE LTD

Unit 10, Carvers Industrial Estate,

Ringwood, Hampshire. BH24 1JS

Tel: +44 (0)333 0110 488

Website: www.propexheatsource.co.uk

Email: info@propexheatsource.co.uk